Bi-block

Bi-block S

FEATURES

  • Electronic control unit.
  • Expansion type with capillary tube.
  • Filter on the liquid line.
  • Provision for cell light connection.
  • Cable for connecting the door heater in low-temperature units.
  • All units are equipped with a fixed-setting low-pressure pressure switch; three-phase units and the STY-STX122 model are also supplied with a fixed-setting high-pressure switch, in accordance with the 2014/68/EU Pressure Equipment Directive. However, upon request, the high-pressure switch can also be supplied on units with 230/1/50Hz voltage.
  • Unit supplied with remote control panel with cable length of 5 m (can be supplied with different lengths up to 20 m on request).
  • External condensate water drain.
  • Resistance in condensate drainage in all medium- and low-temperature units.
  • Wall application of condensing unit, ceiling application of evaporating unit cell.
  • Pipes and cables connecting condensing unit and evaporating unit are supplied in lengths of 5m (10m on request).
  • The tubes and the two condensing and evaporating parts of the unit are already precharged with refrigerant and equipped with quick couplings to facilitate connection.
  • We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the ‘use of optional acces- sories is required. In addition, if the unit is installed outdoors, it is necessary to protect the unit from the weather.

TNTB
Temperatura cella+5/-5 °C-18/-25 °C
Potenza frigorifera500 / 5184 W425 / 3209 W
Volume cella3,1 / 76,8 m³2,8 / 56,3 m³

PRODUCT INFORMATION

  • Electronic control unit.
  • Expansion type with capillary tube.
  • Filter on the liquid line.
  • Provision for cell light connection.
  • Cable for connecting the door heater in low-temperature units.
  • All units are equipped with a fixed-setting low-pressure pressure switch; three-phase units and the STY-STX122 model are also supplied with a fixed-setting high-pressure switch, in accordance with the 2014/68/EU Pressure Equipment Directive. However, upon request, the high-pressure switch can also be supplied on units with 230/1/50Hz voltage.
  • Unit supplied with remote control panel with cable length of 5 m (can be supplied with different lengths up to 20 m on request).
  • External condensate water drain.
  • Resistance in condensate drainage in all medium- and low-temperature units.
  • Wall application of condensing unit, ceiling application of evaporating unit cell.
  • Pipes and cables connecting condensing unit and evaporating unit are supplied in lengths of 5m (10m on request).
  • The tubes and the two condensing and evaporating parts of the unit are already precharged with refrigerant and equipped with quick couplings to facilitate connection.
  • We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the ‘use of optional acces- sories is required. In addition, if the unit is installed outdoors, it is necessary to protect the unit from the weather.