Silenced systems

Silenced systems GS

FEATURES

  • Soundproofed compressor compartment.
  • Crankcase heater on compressor.
  • 6-pole condenser motor fan.
  • Electronic control unit.
  • Expansion type with thermostatic valve.
  • Liquid receiver confirms to the 2014/68/EU “Pressure Equipment” Directive.
  • Liquid line consisting of tap on the receiver, filter and liquid indicator.
  • All units are equipped with low and high pressure switches with fixed calibration, in accordance with the Pressure Equipment Directive 2014/68/EU.
  • Solenoid valve on the liquid line.
  • Piping connections between the condensing unit and evaporator are made without solder taps or flanges.
  • Provision for connection of cell light and door micro.
  • Cable for connecting the door heater in low-temperature units.
  • Direct condensate water discharge.
  • Resistance in the condensate drain.
  • Installation of ‘condensing unit on the floor outside the cell, installation of ‘evaporator on the ceiling inside the cell.
  • Unit supplied with remote control panel with cable length of 5 m (can be supplied with different lengths up to 20 m on request).
  • Condensing unit suitable for outdoor installation. We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the ‘use of optional accessories is required.

TNTB
Temperatura cella+5/-5 °C-18/-25 °C
Potenza frigorifera1000 / 9663 W823 / 5390 W
Volume cella8,53 / 257,74 m³5,29 / 84,18 m³

MODEL VARIANTS

PRODUCT INFORMATION

  • Soundproofed compressor compartment.
  • Crankcase heater on compressor.
  • 6-pole condenser motor fan.
  • Electronic control unit.
  • Expansion type with thermostatic valve.
  • Liquid receiver confirms to the 2014/68/EU “Pressure Equipment” Directive.
  • Liquid line consisting of tap on the receiver, filter and liquid indicator.
  • All units are equipped with low and high pressure switches with fixed calibration, in accordance with the Pressure Equipment Directive 2014/68/EU.
  • Solenoid valve on the liquid line.
  • Piping connections between the condensing unit and evaporator are made without solder taps or flanges.
  • Provision for connection of cell light and door micro.
  • Cable for connecting the door heater in low-temperature units.
  • Direct condensate water discharge.
  • Resistance in the condensate drain.
  • Installation of ‘condensing unit on the floor outside the cell, installation of ‘evaporator on the ceiling inside the cell.
  • Unit supplied with remote control panel with cable length of 5 m (can be supplied with different lengths up to 20 m on request).
  • Condensing unit suitable for outdoor installation. We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the ‘use of optional accessories is required.