HO.RE.CA

HO.RE.CA T

FEATURES

  • Electronic control instrument.
  • Capillary tube expansion.
  • Filter on the liquid line of molecular sieve type in forms 1 and 2 and filter on the liquid line of solid body type in forms 3, 3B, 4 and 5.
  • Cable for connecting door heater in low-temperature unit.
  • The compressors of units forms 4 and 5 are equipped with crankcase preheating resistor.
  • Three-phase units and model TTY-TTX122 are supplied with a fixed calibration high-pressure switch in accordance with Directive 2014/68/EU, “Pressure Equipment.”
  • Low pressure switch in forms 3, 3B, 4 and 5.
  • Liquid separator on the suction line in forms 4 and 5.
  • Condenser fan control pressure switch in models TTZ202, TTZ203, low temperature forms 3, 3B, and all models form 4 and 5.
  • Waste water evaporation pan and overflow pipe for all models form 1, 2 and form 3 in high and medium temperature. Discharge is direct for Form 3 models at low temperature and in all Models of Forms 3B, 4 and 5.
  • Condensate drain heater.
  • Cell wall mounting with hole for pad.
  • We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the ‘use of optional accessories is required. In addition, if the unit is installed outdoors, it is necessary to protect the unit from the weather.

TNTB
Temperatura cella+5/-5 °C-18/-25 °C
Potenza frigorifera370 / 12029 W400 / 5781 W
Volume cella2,2 / 304 m³2,7 / 112,7 m³

MODEL VARIANTS

PRODUCT INFORMATION

  • Electronic control instrument.
  • Capillary tube expansion.
  • Filter on the liquid line of molecular sieve type in forms 1 and 2 and filter on the liquid line of solid body type in forms 3, 3B, 4 and 5.
  • Cable for connecting door heater in low-temperature unit.
  • The compressors of units forms 4 and 5 are equipped with crankcase preheating resistor.
  • Three-phase units and model TTY-TTX122 are supplied with a fixed calibration high-pressure switch in accordance with Directive 2014/68/EU, “Pressure Equipment.”
  • Low pressure switch in forms 3, 3B, 4 and 5.
  • Liquid separator on the suction line in forms 4 and 5.
  • Condenser fan control pressure switch in models TTZ202, TTZ203, low temperature forms 3, 3B, and all models form 4 and 5.
  • Waste water evaporation pan and overflow pipe for all models form 1, 2 and form 3 in high and medium temperature. Discharge is direct for Form 3 models at low temperature and in all Models of Forms 3B, 4 and 5.
  • Condensate drain heater.
  • Cell wall mounting with hole for pad.
  • We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the ‘use of optional accessories is required. In addition, if the unit is installed outdoors, it is necessary to protect the unit from the weather.