Bi-block

Bi-block OV

FEATURES

  • Electronic control unit.
  • Expansion type with thermostatic valve.
  • Solid-body filter on the liquid line.
  • Provision for connection of cell light and door micro.
  • Cable for connecting the door heater in low-temperature units.
  • All units are equipped with a low-pressure and high-pressure pressure switch with fixed calibration, in accordance with the Pressure Equipment Directive 2014/68/EU.
  • Unit supplied with remote control panel with cable length of 5 m (can be supplied with different lengths up to 20 m on request).
  • Direct condensate water discharge.
  • Resistance in the condensate drain.
  • Installation of ‘condensing unit on the floor outside the cell, installation of evaporator on the ceiling inside the cell.
  • Liquid indicator.
  • Solenoid valve on the liquid line in units forms 3I3-3I5 and in all OVFR models. Also available in 1I2-1I3-2I2-2I3 forms upon request.
  • All models are supplied with liquid receiver with safety valve, in accordance with the Pressure Equipment Directive 2014/68/EU.
  • Oil separator on the discharge line in OVFRZ series models.
  • Pressure relief valve on the suction line in OVFRZ series models.
  • Liquid separator on the suction line.
  • The piping connections between the condensing unit and evaporator are made without welding glands or flanges.
  • Compressor preheating.
  • Condenser fan control pressure switch.
  • Condensing unit suitable for outdoor installation. We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the use of optional accessories is required.
  • Weather protection cover.

TNTBPLFR
Temperatura cella+5/-5 °C-18/-25 °C+5/-5, -18/-25 °C-30/-40 °C
Potenza frigorifera370 / 2258 W380 / 1150 W2592 / 23083 W3795 / 7007 W
Volume cella2 / 29,50 m³3 / 12,50 m³24 / 1245 m³/

PRODUCT INFORMATION

  • Electronic control unit.
  • Expansion type with thermostatic valve.
  • Solid-body filter on the liquid line.
  • Provision for connection of cell light and door micro.
  • Cable for connecting the door heater in low-temperature units.
  • All units are equipped with a low-pressure and high-pressure pressure switch with fixed calibration, in accordance with the Pressure Equipment Directive 2014/68/EU.
  • Unit supplied with remote control panel with cable length of 5 m (can be supplied with different lengths up to 20 m on request).
  • Direct condensate water discharge.
  • Resistance in the condensate drain.
  • Installation of ‘condensing unit on the floor outside the cell, installation of evaporator on the ceiling inside the cell.
  • Liquid indicator.
  • Solenoid valve on the liquid line in units forms 3I3-3I5 and in all OVFR models. Also available in 1I2-1I3-2I2-2I3 forms upon request.
  • All models are supplied with liquid receiver with safety valve, in accordance with the Pressure Equipment Directive 2014/68/EU.
  • Oil separator on the discharge line in OVFRZ series models.
  • Pressure relief valve on the suction line in OVFRZ series models.
  • Liquid separator on the suction line.
  • The piping connections between the condensing unit and evaporator are made without welding glands or flanges.
  • Compressor preheating.
  • Condenser fan control pressure switch.
  • Condensing unit suitable for outdoor installation. We recommend using the unit in environments with temperatures above 10°C. When installing in environments with temperatures below 10°C, the use of optional accessories is required.
  • Weather protection cover.